KriegerSonic
Pre-Engineered Models
The models for acoustical doors and soundproof doors that are published here represent a sample of the performance combinations possible. If you do not find what you are looking for, please contact us.
SCIF Compliant Acoustical Doors
THESE ARE PRE-ENGINEERED MODELS • WE CUSTOM MANUFACTURE TO YOUR SPECIFIC NEEDS INCLUDING JUIAF & DCID 6/9 & ICPM 2006-700-7
 
Model Number
SCIF
Sound Group
STC
Weight
Seal
Hinge
U/L Label
Threshold
NC3-SCIF Single 3 Field 45 11.4 NC3 Cam Lift A, B, C ,D, 20 Min. Aluminum



Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

SCIF models to be tested according to ASTM-E336. E90 testing will not achieve SCIF compliance.
These doors assemblies will meet sound attenuation criteria and hardware requirements for each sound group note as outlined in JUIAF and DCID 6/9
Specification

NC3-SCIF Pair 3 Field 45 11.4 NC3 Cam Lift A, B, C ,D, 20 Min. Aluminum



Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

• SCIF models to be tested according to ASTM-E336. E90 testing will not achieve SCIF compliance.
Specification

NC12-SCIF Single 4 Field 50 22.9 NC12 Cam Lift N/A. Aluminum



Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

SCIF models to be tested according to ASTM-E336. E90 testing will not achieve SCIF compliance.
These doors assemblies will meet sound attenuation criteria and hardware requirements for each sound group note as outlined in JUIAF and DCID 6/9
Specification

NC12-SCIF Pair 4 Field 50 22.9 NC12 Cam Lift N/A. Aluminum



Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

SCIF models to be tested according to ASTM-E336. E90 testing will not achieve SCIF compliance.
These doors assemblies will meet sound attenuation criteria and hardware requirements for each sound group note as outlined in JUIAF and DCID 6/9
Specification


Acoustical Magnetic Noise Control Seals
THESE ARE PRE-ENGINEERED MODELS • WE CUSTOM MANUFACTURE TO YOUR ACTUAL NEEDS
 
STC
Model Number
Weight
Seal
1
Hinge
2
U/L
Label
3
Recommended
Max. V/L Area
Hinges
2
Threshold
44 NC6-15-8944 10.2 NC6 C/L BCDE 300 SQ. IN. STD ALUM. OR S.S.



Test report data

Report
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
TL89-246
29 38 38 40 43 42 42 44 48 48 48 44 40 42 45 47 49 52
Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

Doors tested are flush design and 1-3/4" thick.
Specification

45 NC6-18-9345 12.9 NC6 C/L BCDE 300 SQ. IN. STD ALUM. OR S.S.



Test report data

Report
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
TL93-189
29 29 31 38 42 45 47 47 46 44 43 44 42 44 47 47 49 50
Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

Doors tested are flush design and 1-3/4" thick.
Specification

46 NC6-18-9146 12.9 NC6 C/L BCDE 300 SQ. IN. STD ALUM. OR S.S.



Test report data

Report
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
TL-91-211
31 35 39 40 42 41 43 44 48 50 50 48 44 43 44 48 53 55
Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

Doors tested are flush design and 1-3/4" thick.
Specification

46 NC7-19-9346 14.3 NC7 C/L BCDE 1440 SQ. IN. STD ALUM. OR S.S.



Test report data

Report
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
TL93-191
24 32 36 37 39 38 37 41 45 48 49 51 53 54 53 53 55 56
Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

Doors tested are flush design and 1-3/4" thick.
Specification

46 NC7-18-9346 12.9 NC7 C/L BCDE 300 SQ. IN. STD ALUM. OR S.S.



Test report data

Report
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
TL93-190
29 30 30 38 42 45 47 46 46 45 44 46 47 48 50 49 51 52
Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

Doors tested are flush design and 1-3/4" thick.
Specification

46 NC6-22-0346 12.7 NC6 C/L N/A N/A STD ALUM. OR S.S.



Test report data

Report
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
TL03-434
35 39 41 40 42 45 45 46 45 41 42 43 47 49 50 49 49 51
Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

Doors tested are flush design and 2 1/4" thick.
Specification

50 NC7-15-8950 10.2 NC7 C/L BCDE CALL STD ALUM. OR S.S.



Test report data

Report
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
TL89-247
30 37 38 39 40 42 43 45 48 49 51 53 53 53 54 55 56 58
Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

Doors tested are flush design and 1-3/4" thick.
Specification

50 NC7-18-9150 12.9 NC7 C/L ABCDE CALL STD ALUM. OR S.S.



Test report data

Report
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
TL91-210
32 36 39 41 42 41 43 44 49 50 51 52 53 54 55 55 56 57
Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

Doors tested are flush design and 1-3/4" thick.
Specification

51 NC7-17-8951 14.4 NC7 C/L ABCDE CALL STD ALUM. OR S.S.



Test report data

Report
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
TL89-241
34 43 39 40 45 46 46 46 48 50 51 52 53 55 58 58 57 58
Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

Doors tested are flush design and 1-3/4" thick.
Specification


Acoustical Compression Noise Control Seals
THESE ARE PRE-ENGINEERED MODELS • WE CUSTOM MANUFACTURE TO YOUR ACTUAL NEEDS
 
STC
Model Number
Weight
Seal
1
Hinge
2
U/L
Label
3
Recommended
Max. V/L Area
Hinges
2
Threshold
40 NC5-15-0340 8.5 NC5 STD BCDE 300 SQ. IN. C/L ALUM. OR S.S.



Test report data

Report
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
TL03-440
21 26 33 36 36 37 38 40 41 42 41 41 42 41 40 38 38 40
Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

Doors tested are flush design and 1-3/4" thick.
Specification

44 NC3-15A-0344 8.5 NC3 STD BCDE 300 SQ. IN. C/L ALUM. OR S.S.



Test report data

Report
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
TL03-438
21 26 32 37 38 40 43 45 45 45 42 41 43 46 47 47 45 43
Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

Doors tested are flush design and 1-3/4" thick.
Specification

44 NC5-19-0344 14.3 NC5 C/L BCDE 1440 SQ. IN. STD ALUM. OR S.S.



Test report data

Report
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
TL03-430
34 28 28 32 39 44 44 43 42 41 41 43 45 47 50 51 52 52
Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

Doors tested are flush design and 1-3/4" thick.
Specification

45 NC5-15A-0345 8.5 NC5 STD BCDE 300 SQ. IN. C/L ALUM. OR S.S.



Test report data

Report
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
TL03-439
22 26 33 38 38 41 43 45 46 46 45 44 46 47 48 47 46 47
Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

Doors tested are flush design and 1-3/4" thick.
Specification

46 NC5-19FG-9346 14.3 NC5 C/L BCDE 1725 SQ. IN. STD ALUM. OR S.S.



Test report data

Report
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
TL93-192
24 31 36 37 40 38 37 40 44 47 49 52 54 55 54 54 56 56
Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

Doors tested are flush design and 1-3/4" thick.
Specification

49 NC5-18-9149 12.9 NC5 C/L ABCDE CALL STD ALUM. OR S.S.



Test report data

Report
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
TL91-208
32 35 39 41 41 40 43 45 49 50 50 51 52 53 53 49 51 53
Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

Doors tested are flush design and 1-3/4" thick.
Specification

49 NC3-22-0349 12.7 NC3 C/L NA NA STD ALUM. OR S.S.



Test report data

Report
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
TL03-437
35 39 41 40 43 45 44 47 48 48 48 49 50 50 50 52 54 55
Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

Doors tested are flush design and 2 1/4" thick.
Specification

51 NC3-17-8951 14.4 NC3 C/L ABCDE CALL STD ALUM. OR S.S.



Test report data

Report
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
TL89-243
36 47 39 40 45 46 45 47 49 50 51 53 53 54 55 57 56 57
Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

Doors tested are flush design and 1-3/4" thick.
Specification

52 NC5-19-9352 12.4 NC5 C/L ABCDE CALL NA ALUM. OR S.S.



Test report data

Report
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
TL93-195
31 34 42 48 44 46 49 48 51 51 52 53 53 55 54 55 55 56
Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

Doors tested are flush design and 1-3/4" thick.
Specification

53 NC5-19-9353 12.4 NC5 C/L ABCDE CALL NA ALUM. OR S.S.



Test report data

Report
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
TL93-193
32 34 43 49 45 49 50 49 53 53 55 54 54 55 55 55 57 58
Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

Doors tested are flush design and 1-3/4" thick.
Specification

55 NC12-30-9155 22.7 NC12 C/L NA NA NA ALUM. OR S.S.



Test report data

Report
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
TL91-200
39 39 42 43 45 46 50 50 52 54 56 56 59 60 62 63 64 64
Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

Doors tested are flush design and 3" thick.
Specification


Acoustical Wood Doors w/Compression Noise Control Seals for Soundproofing
THESE ARE PRE-ENGINEERED MODELS • WE CUSTOM MANUFACTURE TO YOUR ACTUAL NEEDS
 
STC
Model Number
Weight
Seal
1
Hinge
2
U/L
Label
3
Recommended
Max. V/L Area
Hinges
2
Threshold
46 NC3-WD1-9146 7.0 NC3 C/L C CALL NA ALUM. OR S.S.



Test report data

Report
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
TL91-206
27 24 30 35 37 38 43 45 46 47 46 47 50 51 52 52 52 52
Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

Doors tested are flush design and 1-3/4" thick.
Specification

47 NC5-WD1-9147 7.0 NC5 C/L C CALL NA ALUM. OR S.S.



Test report data

Report
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
TL91-207
27 24 31 35 37 38 43 45 47 48 49 50 50 51 53 54 54 55
Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

Doors tested are flush design and 1-3/4" thick.
Specification

49 NC3-WD2-9149 11.0 NC3 C/L C CALL NA ALUM. OR S.S.



Test report data

Report
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
TL91-208
32 35 39 41 41 40 43 45 49 50 50 51 52 53 53 49 51 53
Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

Doors tested are flush design and 1-3/4" thick.
Specification

50 NC3-WD2-8550 11.0 NC3 C/L C CALL NA ALUM. OR S.S.



Test report data

Report
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
TL85-327
27 29 36 39 42 45 46 50 49 49 49 50 50 54 56 56 55 55
Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

Doors tested are flush design and 1-3/4" thick.
Specification

53 NC5-WD3-9353 12.5 NC5 C/L C CALL NA ALUM. OR S.S.



Test report data

Report
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
TL93-193
32 34 43 49 45 49 50 49 53 53 55 54 54 55 55 55 57 58
Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

Doors tested are flush design and 1-3/4" thick.
Specification


Acoustical Pairs of Doors
THESE ARE PRE-ENGINEERED MODELS • WE CUSTOM MANUFACTURE TO YOUR ACTUAL NEEDS
 
STC
Model Number
Weight
Seal
1
Hinge
2
U/L
Label
3
Recommended
Max. V/L Area
Hinges
2
Threshold
45 NC6-216-8945 14.4 NC6/A1 C/L BCDE 300 SQ. IN. STD ALUM. OR S.S.



Test report data

Report
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
TL89-228
35 40 37 40 45 45 46 46 47 48 47 46 43 41 43 47 49 49
Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

Doors tested are flush design and 1-3/4" thick.
Specification

46 NC3-216-8946 14.4 NC3/A1 C/L BCDE 300 SQ. IN. STD ALUM. OR S.S.



Test report data

Report
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
TL89-239
35 42 36 40 45 44 45 45 46 45 44 44 44 45 47 49 50 50
Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

Doors tested are flush design and 1-3/4" thick.
Specification

47 NC6-216-8947 14.4 NC6/A1 C/L BCDE 216 SQ. IN. STD ALUM. OR S.S.



Test report data

Report
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
TL89-235
34 32 38 42 49 46 48 47 48 49 48 45 45 44 46 49 50 51
Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

Doors tested are flush design and 1-3/4" thick.
Specification

49 NC6-216-8949 14.4 NC6/A2 C/L ABCDE CALL NA ALUM. OR S.S.



Test report data

Report
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
TL89-236
34 37 36 40 45 45 48 47 48 49 49 51 50 46 48 50 51 52
Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

Doors tested are flush design and 1-3/4" thick.
Specification

51 NC7-216-8951 14.4 NC7/A2 C/L ABCDE CALL NA ALUM. OR S.S.



Test report data

Report
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
TL89-232
36 40 36 40 45 44 47 47 48 49 50 51 53 54 57 58 57 56
Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

Doors tested are flush design and 1-3/4" thick.
Specification


Acoustical Sliding Man Doors
THESE ARE PRE-ENGINEERED MODELS • WE CUSTOM MANUFACTURE TO YOUR ACTUAL NEEDS
 
STC
Model Number
Weight
Seal
1
Hinge
2
U/L
Label
3
Recommended
Max. V/L Area
Hinges
2
Threshold
40 NC6-225SL-9840 15.5 NC6 NA NA NA NA ALUM. OR S.S.



Test report data

Report
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
TL98-426
29 33 37 42 41 41 40 39 36 36 37 36 38 41 44 43 46 46
Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

Sliding Man Door includes a manual or power operated track and trolley system.
Specification


Acoustical Noise Control View Windows
THESE ARE PRE-ENGINEERED MODELS • WE CUSTOM MANUFACTURE TO YOUR ACTUAL NEEDS
 
STC
Model Number
Thickness
Weight
Area Tested
Glass Type
Glazing Type
47 NCV-2525MW-47 8" 10.5 21 SQ. FT. 1/4" MONO x 1/4" WIRE NEOPRENE



Test report data

Report
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
TL88-109
30 36 30 34 40 42 41 47 50 50 46 52 52 45 46 53 54 60
Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

Specification

49 NCV-2525L-49 8" 11.0 21 SQ. FT. 1/4" LAM x 1/4" LAM NEOPRENE



Test report data

Report
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
TL88-107
22 38 33 34 41 42 41 47 50 50 46 52 52 55 54 57 59 63
Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

Specification

50 NCV-3825L-50 8" 12.4 21 SQ. FT. 1/4" LAM x 3/8" LAM NEOPRENE



Test report data

Report
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
TL88-106
29 37 35 37 42 43 42 48 50 50 46 52 52 56 55 58 60 64
Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

Specification

52 NCV-2525-9852 9 5/8" 14.0 21 SQ. FT. 1/4" LAM x 1/4" LAM NEOPRENE



Test report data

Report
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
TL98-423
30 30 38 39 41 43 44 49 53 54 57 60 61 61 61 63 64 62
Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

Specification

53 NCV-2537-9853 9 5/8" 15.5 21 SQ. FT. 1/4" LAM x 3/8" LAM NEOPRENE



Test report data

Report
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
TL98-422
29 34 38 40 42 44 45 52 54 54 57 59 60 61 62 63 64 63
Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

Specification

56 NCV-3775-9856 9 5/8" 21.5 21 SQ. FT. 3/8" LAM x 3/4" LAM NEOPRENE



Test report data

Report
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
TL98-421
31 37 40 42 46 51 52 54 55 54 57 61 63 64 64 65 64 63
Downloads

Generic Frame
DWG File DWF File PDF File

NOTE

Specification


Legend
1.
Noise Control Seals and Astragals are KriegerSonic
®
proprietary design.
2.
Hinge type shown on tested door (see options column for alternate hinge). STD = standard mortise butt hinge. C/L = Cam lift hinge. Cam lift hinges are KriegerSonic
®
proprietary design and are furnished with the door assembly. Cam lift hinges will increase the force required to fully operate a door, this should be considered for facilities with handicap codes.
3.
Doors are available with up to 3 hour U/L label. We also offer positive pressure tests in accordance with Standards: U/L 10C and UBC 7-2 and 7-4.