Model Number |
SCIF Sound Group |
STC |
Weight |
Seal |
Hinge |
U/L Label |
Threshold |
| NC3-SCIF Single | 3 | Field 45 | 11.4 | NC3 | Cam Lift | A, B, C ,D, 20 Min. | Aluminum |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | SCIF models to be tested according to ASTM-E336. E90 testing will not achieve SCIF compliance. | |
| • | These doors assemblies will meet sound attenuation criteria and hardware requirements for each sound group note as outlined in JUIAF and DCID 6/9 | |
| • | Specification |
| NC3-SCIF Pair | 3 | Field 45 | 11.4 | NC3 | Cam Lift | A, B, C ,D, 20 Min. | Aluminum |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • SCIF models to be tested according to ASTM-E336. E90 testing will not achieve SCIF compliance. • Specification |
| NC12-SCIF Single | 4 | Field 50 | 22.9 | NC12 | Cam Lift | N/A. | Aluminum |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | SCIF models to be tested according to ASTM-E336. E90 testing will not achieve SCIF compliance. | |
| • | These doors assemblies will meet sound attenuation criteria and hardware requirements for each sound group note as outlined in JUIAF and DCID 6/9 | |
| • | Specification |
| NC12-SCIF Pair | 4 | Field 50 | 22.9 | NC12 | Cam Lift | N/A. | Aluminum |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | SCIF models to be tested according to ASTM-E336. E90 testing will not achieve SCIF compliance. | |
| • | These doors assemblies will meet sound attenuation criteria and hardware requirements for each sound group note as outlined in JUIAF and DCID 6/9 | |
| • | Specification |
STC |
Model Number |
Weight |
Seal 1 |
Hinge 2 |
U/L Label 3 |
Recommended Max. V/L Area |
Hinges 2 |
Threshold |
| 44 | NC6-15-8944 | 10.2 | NC6 | C/L | BCDE | 300 SQ. IN. | STD | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL89-246 |
29 | 38 | 38 | 40 | 43 | 42 | 42 | 44 | 48 | 48 | 48 | 44 | 40 | 42 | 45 | 47 | 49 | 52 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification |
| 45 | NC6-18-9345 | 12.9 | NC6 | C/L | BCDE | 300 SQ. IN. | STD | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL93-189 |
29 | 29 | 31 | 38 | 42 | 45 | 47 | 47 | 46 | 44 | 43 | 44 | 42 | 44 | 47 | 47 | 49 | 50 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification |
| 46 | NC6-18-9146 | 12.9 | NC6 | C/L | BCDE | 300 SQ. IN. | STD | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL-91-211 |
31 | 35 | 39 | 40 | 42 | 41 | 43 | 44 | 48 | 50 | 50 | 48 | 44 | 43 | 44 | 48 | 53 | 55 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification |
| 46 | NC7-19-9346 | 14.3 | NC7 | C/L | BCDE | 1440 SQ. IN. | STD | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL93-191 |
24 | 32 | 36 | 37 | 39 | 38 | 37 | 41 | 45 | 48 | 49 | 51 | 53 | 54 | 53 | 53 | 55 | 56 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification |
| 46 | NC7-18-9346 | 12.9 | NC7 | C/L | BCDE | 300 SQ. IN. | STD | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL93-190 |
29 | 30 | 30 | 38 | 42 | 45 | 47 | 46 | 46 | 45 | 44 | 46 | 47 | 48 | 50 | 49 | 51 | 52 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification |
| 46 | NC6-22-0346 | 12.7 | NC6 | C/L | N/A | N/A | STD | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL03-434 |
35 | 39 | 41 | 40 | 42 | 45 | 45 | 46 | 45 | 41 | 42 | 43 | 47 | 49 | 50 | 49 | 49 | 51 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 2 1/4" thick. | |
| • | Specification |
| 50 | NC7-15-8950 | 10.2 | NC7 | C/L | BCDE | CALL | STD | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL89-247 |
30 | 37 | 38 | 39 | 40 | 42 | 43 | 45 | 48 | 49 | 51 | 53 | 53 | 53 | 54 | 55 | 56 | 58 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification |
| 50 | NC7-18-9150 | 12.9 | NC7 | C/L | ABCDE | CALL | STD | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL91-210 |
32 | 36 | 39 | 41 | 42 | 41 | 43 | 44 | 49 | 50 | 51 | 52 | 53 | 54 | 55 | 55 | 56 | 57 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification |
| 51 | NC7-17-8951 | 14.4 | NC7 | C/L | ABCDE | CALL | STD | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL89-241 |
34 | 43 | 39 | 40 | 45 | 46 | 46 | 46 | 48 | 50 | 51 | 52 | 53 | 55 | 58 | 58 | 57 | 58 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification |
STC |
Model Number |
Weight |
Seal 1 |
Hinge 2 |
U/L Label 3 |
Recommended Max. V/L Area |
Hinges 2 |
Threshold |
| 40 | NC5-15-0340 | 8.5 | NC5 | STD | BCDE | 300 SQ. IN. | C/L | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL03-440 |
21 | 26 | 33 | 36 | 36 | 37 | 38 | 40 | 41 | 42 | 41 | 41 | 42 | 41 | 40 | 38 | 38 | 40 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification |
| 44 | NC3-15A-0344 | 8.5 | NC3 | STD | BCDE | 300 SQ. IN. | C/L | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL03-438 |
21 | 26 | 32 | 37 | 38 | 40 | 43 | 45 | 45 | 45 | 42 | 41 | 43 | 46 | 47 | 47 | 45 | 43 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification |
| 44 | NC5-19-0344 | 14.3 | NC5 | C/L | BCDE | 1440 SQ. IN. | STD | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL03-430 |
34 | 28 | 28 | 32 | 39 | 44 | 44 | 43 | 42 | 41 | 41 | 43 | 45 | 47 | 50 | 51 | 52 | 52 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification |
| 45 | NC5-15A-0345 | 8.5 | NC5 | STD | BCDE | 300 SQ. IN. | C/L | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL03-439 |
22 | 26 | 33 | 38 | 38 | 41 | 43 | 45 | 46 | 46 | 45 | 44 | 46 | 47 | 48 | 47 | 46 | 47 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification |
| 46 | NC5-19FG-9346 | 14.3 | NC5 | C/L | BCDE | 1725 SQ. IN. | STD | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL93-192 |
24 | 31 | 36 | 37 | 40 | 38 | 37 | 40 | 44 | 47 | 49 | 52 | 54 | 55 | 54 | 54 | 56 | 56 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification |
| 49 | NC5-18-9149 | 12.9 | NC5 | C/L | ABCDE | CALL | STD | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL91-208 |
32 | 35 | 39 | 41 | 41 | 40 | 43 | 45 | 49 | 50 | 50 | 51 | 52 | 53 | 53 | 49 | 51 | 53 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification |
| 49 | NC3-22-0349 | 12.7 | NC3 | C/L | NA | NA | STD | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL03-437 |
35 | 39 | 41 | 40 | 43 | 45 | 44 | 47 | 48 | 48 | 48 | 49 | 50 | 50 | 50 | 52 | 54 | 55 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 2 1/4" thick. | |
| • | Specification |
| 51 | NC3-17-8951 | 14.4 | NC3 | C/L | ABCDE | CALL | STD | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL89-243 |
36 | 47 | 39 | 40 | 45 | 46 | 45 | 47 | 49 | 50 | 51 | 53 | 53 | 54 | 55 | 57 | 56 | 57 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification |
| 52 | NC5-19-9352 | 12.4 | NC5 | C/L | ABCDE | CALL | NA | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL93-195 |
31 | 34 | 42 | 48 | 44 | 46 | 49 | 48 | 51 | 51 | 52 | 53 | 53 | 55 | 54 | 55 | 55 | 56 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification |
| 53 | NC5-19-9353 | 12.4 | NC5 | C/L | ABCDE | CALL | NA | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL93-193 |
32 | 34 | 43 | 49 | 45 | 49 | 50 | 49 | 53 | 53 | 55 | 54 | 54 | 55 | 55 | 55 | 57 | 58 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification |
| 55 | NC12-30-9155 | 22.7 | NC12 | C/L | NA | NA | NA | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL91-200 |
39 | 39 | 42 | 43 | 45 | 46 | 50 | 50 | 52 | 54 | 56 | 56 | 59 | 60 | 62 | 63 | 64 | 64 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 3" thick. | |
| • | Specification |
STC |
Model Number |
Weight |
Seal 1 |
Hinge 2 |
U/L Label 3 |
Recommended Max. V/L Area |
Hinges 2 |
Threshold |
| 46 | NC3-WD1-9146 | 7.0 | NC3 | C/L | C | CALL | NA | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL91-206 |
27 | 24 | 30 | 35 | 37 | 38 | 43 | 45 | 46 | 47 | 46 | 47 | 50 | 51 | 52 | 52 | 52 | 52 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification |
| 47 | NC5-WD1-9147 | 7.0 | NC5 | C/L | C | CALL | NA | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL91-207 |
27 | 24 | 31 | 35 | 37 | 38 | 43 | 45 | 47 | 48 | 49 | 50 | 50 | 51 | 53 | 54 | 54 | 55 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification |
| 49 | NC3-WD2-9149 | 11.0 | NC3 | C/L | C | CALL | NA | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL91-208 |
32 | 35 | 39 | 41 | 41 | 40 | 43 | 45 | 49 | 50 | 50 | 51 | 52 | 53 | 53 | 49 | 51 | 53 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification |
| 50 | NC3-WD2-8550 | 11.0 | NC3 | C/L | C | CALL | NA | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL85-327 |
27 | 29 | 36 | 39 | 42 | 45 | 46 | 50 | 49 | 49 | 49 | 50 | 50 | 54 | 56 | 56 | 55 | 55 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification |
| 53 | NC5-WD3-9353 | 12.5 | NC5 | C/L | C | CALL | NA | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL93-193 |
32 | 34 | 43 | 49 | 45 | 49 | 50 | 49 | 53 | 53 | 55 | 54 | 54 | 55 | 55 | 55 | 57 | 58 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification |
STC |
Model Number |
Weight |
Seal 1 |
Hinge 2 |
U/L Label 3 |
Recommended Max. V/L Area |
Hinges 2 |
Threshold |
| 45 | NC6-216-8945 | 14.4 | NC6/A1 | C/L | BCDE | 300 SQ. IN. | STD | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL89-228 |
35 | 40 | 37 | 40 | 45 | 45 | 46 | 46 | 47 | 48 | 47 | 46 | 43 | 41 | 43 | 47 | 49 | 49 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification |
| 46 | NC3-216-8946 | 14.4 | NC3/A1 | C/L | BCDE | 300 SQ. IN. | STD | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL89-239 |
35 | 42 | 36 | 40 | 45 | 44 | 45 | 45 | 46 | 45 | 44 | 44 | 44 | 45 | 47 | 49 | 50 | 50 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification |
| 47 | NC6-216-8947 | 14.4 | NC6/A1 | C/L | BCDE | 216 SQ. IN. | STD | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL89-235 |
34 | 32 | 38 | 42 | 49 | 46 | 48 | 47 | 48 | 49 | 48 | 45 | 45 | 44 | 46 | 49 | 50 | 51 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification |
| 49 | NC6-216-8949 | 14.4 | NC6/A2 | C/L | ABCDE | CALL | NA | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL89-236 |
34 | 37 | 36 | 40 | 45 | 45 | 48 | 47 | 48 | 49 | 49 | 51 | 50 | 46 | 48 | 50 | 51 | 52 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification |
| 51 | NC7-216-8951 | 14.4 | NC7/A2 | C/L | ABCDE | CALL | NA | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL89-232 |
36 | 40 | 36 | 40 | 45 | 44 | 47 | 47 | 48 | 49 | 50 | 51 | 53 | 54 | 57 | 58 | 57 | 56 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Doors tested are flush design and 1-3/4" thick. | |
| • | Specification |
STC |
Model Number |
Weight |
Seal 1 |
Hinge 2 |
U/L Label 3 |
Recommended Max. V/L Area |
Hinges 2 |
Threshold |
| 40 | NC6-225SL-9840 | 15.5 | NC6 | NA | NA | NA | NA | ALUM. OR S.S. |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL98-426 |
29 | 33 | 37 | 42 | 41 | 41 | 40 | 39 | 36 | 36 | 37 | 36 | 38 | 41 | 44 | 43 | 46 | 46 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Sliding Man Door includes a manual or power operated track and trolley system. | |
| • | Specification |
STC |
Model Number |
Thickness |
Weight |
Area Tested |
Glass Type |
Glazing Type |
| 47 | NCV-2525MW-47 | 8" | 10.5 | 21 SQ. FT. | 1/4" MONO x 1/4" WIRE | NEOPRENE |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL88-109 |
30 | 36 | 30 | 34 | 40 | 42 | 41 | 47 | 50 | 50 | 46 | 52 | 52 | 45 | 46 | 53 | 54 | 60 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Specification |
| 49 | NCV-2525L-49 | 8" | 11.0 | 21 SQ. FT. | 1/4" LAM x 1/4" LAM | NEOPRENE |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL88-107 |
22 | 38 | 33 | 34 | 41 | 42 | 41 | 47 | 50 | 50 | 46 | 52 | 52 | 55 | 54 | 57 | 59 | 63 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Specification |
| 50 | NCV-3825L-50 | 8" | 12.4 | 21 SQ. FT. | 1/4" LAM x 3/8" LAM | NEOPRENE |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL88-106 |
29 | 37 | 35 | 37 | 42 | 43 | 42 | 48 | 50 | 50 | 46 | 52 | 52 | 56 | 55 | 58 | 60 | 64 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Specification |
| 52 | NCV-2525-9852 | 9 5/8" | 14.0 | 21 SQ. FT. | 1/4" LAM x 1/4" LAM | NEOPRENE |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL98-423 |
30 | 30 | 38 | 39 | 41 | 43 | 44 | 49 | 53 | 54 | 57 | 60 | 61 | 61 | 61 | 63 | 64 | 62 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Specification |
| 53 | NCV-2537-9853 | 9 5/8" | 15.5 | 21 SQ. FT. | 1/4" LAM x 3/8" LAM | NEOPRENE |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL98-422 |
29 | 34 | 38 | 40 | 42 | 44 | 45 | 52 | 54 | 54 | 57 | 59 | 60 | 61 | 62 | 63 | 64 | 63 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Specification |
| 56 | NCV-3775-9856 | 9 5/8" | 21.5 | 21 SQ. FT. | 3/8" LAM x 3/4" LAM | NEOPRENE |
Report |
100 |
125 |
160 |
200 |
250 |
315 |
400 |
500 |
630 |
800 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
4000 |
5000 |
TL98-421 |
31 | 37 | 40 | 42 | 46 | 51 | 52 | 54 | 55 | 54 | 57 | 61 | 63 | 64 | 64 | 65 | 64 | 63 |
Generic Frame |
DWG File |
DWF File |
PDF File |
| • | Specification |